In short
- NZS 3604 deals with light timber buildings and has no design tables for garden or boundary retaining walls.
- A wall has to satisfy clause B1 of the Building Code, by engineering or a supplier's tested design.
- The H4 and H5 stamps on wall timber are defined in NZS 3640.
- A house close to a wall or bank can fall outside NZS 3604 and need engineering too.
People search for NZS 3604 retaining wall details because 3604 is the standard most builders know best. It is the document that lets a timber-framed house be designed from tables, without an engineer. The short answer is that it does not do the same job for free-standing retaining walls. This guide explains what 3604 does say that touches on walls, and where the rules for walls actually sit.
What NZS 3604 is
NZS 3604 Timber-framed buildings is cited by the Building Code as an acceptable way to design light timber buildings up to a certain size on what it calls good ground. Follow its tables for piles, bearers, joists, studs and bracing and you have a compliant structure. Its scope is buildings. A wall holding back a bank in the garden is not a building element under 3604, and the standard has no span tables or pole schedules for one.
Where 3604 does matter near a wall
Good ground and slopes
The standard only applies where the house foundations bear on good ground, and it restricts how close foundations can be to the top of a bank or cut. If a house sits near the top of a retaining wall, its footings may load the wall. If it sits at the foot of one, the wall is protecting the house. In either case the foundation design can fall outside 3604, and both the house and the wall then need specific engineering design. This is common on Wellington hill sections.
Durability
3604 refers to treatment and fixing requirements for timber and steel in different exposure zones. Those same principles apply to wall timber and fixings: more protection in the ground and more near the sea.
Low foundation walls
3604 and its companion standard for masonry buildings include details for foundation walls of a house that hold back a small height of soil. Those are part of the building's foundation, built to the standard's limits. They are not a licence to design a garden retaining wall from the same tables.
What governs retaining walls
Building Code clause B1 Structure
Every retaining wall, consented or exempt, has to meet B1: it must withstand the loads it is likely to experience without collapsing or deforming badly. There are two usual routes to showing that.
- Specific engineering design. A chartered professional engineer calculates soil, water, surcharge and earthquake loads for the site and sizes the wall. This is the route for anything needing consent.
- A proprietary system's tested design. Suppliers of segmental block, concrete sleeper and crib systems publish design tables prepared by engineers for stated heights and soil conditions. Within those limits a builder can follow the tables.
Building Code clause B2 Durability
Structural elements that are hard to replace must last at least 50 years. For timber walls that drives the treatment level. For steel it drives the galvanising or the choice of stainless.
NZS 3640 timber treatment
This is the standard behind the H numbers stamped on treated timber.
| Hazard class | Meant for | Use in a wall |
|---|---|---|
| H3.2 | Outdoors, above ground | Fence palings or capping only |
| H4 | In contact with the ground | Rails, lagging and sleepers against soil |
| H5 | In the ground, critical structural use | Poles and posts |
| H6 | Sea water | Marine walls |
Using H3 timber below ground is one of the most common reasons a timber wall rots out inside 10 years.
Clause F4 and E1
F4 Safety from falling requires a barrier where the drop is 1 metre or more. E1 Surface water means drainage from the wall must be disposed of properly and not sent onto a neighbour.
Earthquake design
For engineered walls, national geotechnical guidance sets out how to allow for earthquake shaking. In a high-hazard region like Wellington that typically means deeper poles, larger footings or more reinforcing than the same wall would need in a low-hazard part of the country. An exempt low wall is not usually analysed this way, which is one more reason to keep exempt walls genuinely low and unloaded.
What this means when you hire a builder
- If a quote says the wall is built to NZS 3604, ask what is meant. The treatment and fixing guidance may be relevant. The structural design is not in that standard.
- For a wall up to 1.5 metres with no surcharge, ask what the pole size, spacing and depth are based on: a supplier's table, an engineer's standard detail or experience.
- For anything taller or loaded, expect an engineer's drawings and a PS1, and a consent.
- Check the timber stamps on delivery. H5 on poles, H4 on rails.
The timber wall design guide gives the rules of thumb for pole walls, and the regulations guide covers consent. To have a wall looked at, call 04 887 1262.
Questions people ask
Is there an NZS 3604 table for retaining wall pole sizes?
No. The standard has pile and pole tables for building foundations, not for walls resisting soil. Pole sizes for retaining walls come from engineering design or a supplier's published tables.
Which standard do I quote for retaining wall timber?
NZS 3640 for the treatment level: H5 for poles and posts in the ground, H4 for rails and other timber touching soil.
Can a builder design a retaining wall without an engineer?
For a wall within the consent exemption, yes, though it must still meet the Building Code. Good builders work from supplier tables or engineer-prepared standard details. Anything over 1.5 metres or carrying a load needs an engineer.